Tracking Resolution Requirements
in the
Meson Spectroscopy Facility at Jefferson Lab
Curtis A. Meyer
October 20, 1998
In order to understand the resolution requirements
of the HALL D detector, the MCFast program has been
used to simulate the tracking elements in the LASS solenoidal
field at B=2.24 T. The tracks have been generated at 10 distinct
total momenta, and then binned in
wide bins from
to
. These tracks have then been tracked through the
detector as shown in figure 1.
Figure:
A schematic drawing of the tracking
elements in the HALL D detector. All dimensions are in meters.
Shown is a side view along the length of the detector system. The large
rectangle is the central drift chamber, (CDC); the smaller rectangle
closer to the target is the central vertex tracker, (CVT); the three
forward rectangular regions are the forward tracking chambers, (FTC);
and the six small rectangles close to the beam line are the forward
beam line tracker, (FBT).
 |
The default detectors has four tracking systems in it. The large rectangular
box around the target is the central drift chamber, (CDC), a cylindrical
chamber with 16 drift layers going out radially. It's nominal
resolution
is
. There are also six stereo layers at angles of
, and
cathode strips on the inner and outer radii. The cathode strips have a nominal
resolution in z. The innermost layer is at r=15 cm, and the outermost
is at r=60 cm. The chamber extends from z=-75 cm to z=175 cm.
The smaller rectangle just around the target is a 5-layer vertexing chamber,
the central vertex chamber, (CVT). This has a nominal
resolution, but provides no z information. The innermost layer is at r=4 cm and
the outermost is at r=12 cm. The chamber extends from z=-30 cm to z=60 cm.
The three thin boxes in the forward region are 6-layer disk-shaped
forward tracking chambers, (FTC). These provide two planes each of u,
v and y planes, with a nominal resolution of
in each plane. These
start at r=15cm and extend out to r=60cm. They are positioned at
z=220 cm, z=280 cm and z=340 cm.
The six small boxes just outside the beam pipe are high resolution,
three-plane tracking chambers, the forward beam line tracker,
(FBT). These provide nominally
resolution close to the beam pipe.
The chambers start at r=2.5cm and extend to r=13cm. They are placed at
z=100 cm, z=150 cm, z=200 cm, z=250 cm, z=300 cm and z=350 cm.
Each plane is nominally
of silicon.
The conclusions reached in this report are by no means final. The detector
sizes and positions are based on Jim Mueller's talk at the June '98 meeting at
Jefferson Lab, and have not been significantly varied. The default resolutions
have only been educated guesses, and based on this report, it will be seen that
several are incorrect. There has also been insufficient time to optimize
the size and placement of detector planes, and it is likely that real estate
will have to be forfeited outside the 60 cm radius for other detector systems.
Table:
The initial geometry and resolution specifications
of the detector.
| Detector |
4c||Global Geometry |
Planes |
Resolution |
|
|
|
| System |
rmin |
rmax |
zmin |
zmax |
|
|
| CVC |
3.00 cm |
14.00 cm |
-30.0 cm |
45.0 cm |
5 |
 |
| CDC |
15.00 cm |
60.00 cm |
-75.0 cm |
175.0 cm |
2 |
 |
| CDC |
15.00 cm |
60.00 cm |
-75.0 cm |
175.0 cm |
16 |
 |
| FTC1 |
10.00 cm |
60.00 cm |
215.0 cm |
225.0 cm |
6 |
 |
| FTC2 |
10.00 cm |
60.00 cm |
275.0 cm |
285.0 cm |
6 |
 |
| FTC3 |
10.00 cm |
60.00 cm |
35.0 cm |
345.0 cm |
6 |
 |
| FBT1 |
2.50 cm |
13.00 cm |
99.0 cm |
101.0 cm |
3 |
 |
| FBT2 |
2.50 cm |
13.00 cm |
149.0 cm |
151.0 cm |
3 |
 |
| FBT3 |
2.50 cm |
13.00 cm |
199.0 cm |
201.0 cm |
3 |
 |
| FBT4 |
2.50 cm |
13.00 cm |
249.0 cm |
251.0 cm |
3 |
 |
| FBT5 |
2.50 cm |
13.00 cm |
299.0 cm |
301.0 cm |
3 |
 |
| FBT6 |
2.50 cm |
13.00 cm |
349.0 cm |
351.0 cm |
3 |
 |
The Forward Beam line Tracker, (FBT), is the set of six high-resolution
chambers that sit near the beam pipe in the forward region as shown in
figure 1. In figure 2 are plotted the
total momentum resolution,
, as a function of
as measured from the beam direction. There are ten curves for p ranging from
0.250 GeV/c up to 5.000 GeV/c. The FBT affects only the forward most
two bins,
and
.
The first three plots in figure 2 are for a nominal resolution
of
,
and
with material (silicon) in the detectors.
The fourth plot has
resolution, but the silicon has been replaced
with air. The first three plots show that the resolution in the most forward
bin is unaffected by the chamber resolution, and only the removal of material
to reduce multiple scattering improves the momentum resolution.
This effect is seen more clearly in figures 3
to 6. These figures show
in each momentum bin in the most forward angular bin.
Figure 3 has both the beam-pipe and the mass in
the chambers removed, but the chambers retain their
resolution. Figure 4 puts the beam pipe back in,
(
thick Be pipe at a radius of 2.50 cm and extending
the entire length of the solenoid). Finally, figure 5
has the beam-pipe removed, but the material in these chambers put
back in.
The effect of the chamber resolution can be seen in figure 6
which has
resolution, figure 7 which has
resolution and figure 8 which has
resolution.
The bottom line is that the resolution does not have a significant impact
on the momentum resolution. The major role is played by the material --
this region is multiple scattering limited. However, the fact that the
resolution is degraded does not mean that these chambers are unimportant.
These fill an important gap in the solid angle of the detector, and are
key to good efficiency.
In fact, as one final test we have set the resolution to
and
replaced the material with gas -- essentially gas filled drift or wire
chambers. In figure 9 are shown the resolution as a
funtion of momentum in the most forward angular bin. One can see that
this is in fact better than most of the plots for high resolution silicon
detectors. Unless we can develop a zero-mass chamber with extremely
high resolution, something much simpler will suffice.
Figure:
Total momentum resolution ,
,as a function
of
for various momenta. This figure varies the resolution of the
FBT system. The upper left figure has all detectors with their
nominal resolutions, (
for the forward), (see Fig. 6).
The upper right has
resolution, (see Fig. 7), and
the lower left has
resolutions, (see Fig. 8). The
lower right figure has most of the mass removed from the forward chambers with
the
resolution, (see Fig. 4). Only the lowest two
angular bins are affected by this resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. Most of the mass of the chambers and the beam pipe
have been removed to minimize multiple scattering. The detectors have a
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. Most of the mass of the chambers has been removed
to minimize multiple scattering. The detectors have a
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. The beam-pipe has been removed, but the chambers still
have mass, and the detectors have a
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. The detectors have
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. The detector has
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. The detector has
resolution.
 |
Figure:
Resolution as a function of momentum in the
most forward angular bins. The chambers have been replaced with a
resolution chamber filled with gas, rather than silicon.
 |
The Central Vertex Tracker, CVT, is a five-layer cylindrical
chamber with only
information from an inner radius of 3.00 cm
and an outer radius of 14.00 cm. The nominal
resolution is
set to
. Figure 10 shows the effect of the resolution
on the overall momentum resolution,
. The upper left plot
is for
, the upper right is for
and the lower left is for
. This chamber contributes in the
to
region in
, and while there is a noticeable improvement in the
momentum resolution of 5GeV/c tracks in this region, even with
resolution, most of the tracks will be measured to better than 2%.
Figure:
Total momentum resolution,
, as a function of the resolution of the central vertex tracker. The upper left figure
has
resolution, the upper right has the nominal
resolution, and the lower left has
resolution.
 |
The Central Drift Chamber, CDC, is a sixteen-layer cylindrical
chamber with cathode strips measuring the z-coordinate at the inner
and outer radii. It extends from 15.0 cm to 60.0 cm in
radius, and the
resolution is nominally
. There are
six stereo layers ( 5,6,9 and 10 at +0.104 radians and 7 and 8 at -0.104
radians). The resolution,
as a function of chamber
resolution is shown in figures 11 and 12.
Figure 11 shows the effect of varying the
resolution.
The upper left plot is for
, the upper right is for
,and the lower left is for
resolution. Figure 12
shows the effect of varying the z resolution of the cathode strips. The
upper left plot is for
, the upper right is for
and
the lower left is for
resolutions.
Figure:
Total momentum resolution,
, as a function
of the resolution of the central drift chamber. The upper left figure has
resolution, while the upper right has the nominal
.The lower left has
resolution.
 |
Figure:
Total momentum resolution,
, as a function
of the z-resolution of the cathode strips. The upper left figure has
resolution, while the upper right has the nominal
resolution. The lower left has
resolution.
 |
The Forward Tracking Chambers, (FTC), consist of three packages of
six-plane drift chambers for measuring tracks down-stream of the CTC.
The primary purpose of this chamber is to accurately measure the momentum
of fast particles that come out of the downstream end of the CTC. In
figure 13 are plotted
versus
for
different resolutions in the FTC. The upper left plot has
resolution, the upper right has the nominal
's. The lower left
has
and the lower right has
. The bins that are most
affected by these chambers are the
to about
angles,
In figures 14 to 17 are shown the resolution in
the
to
bin for the same resolutions.
Figure:
Total momentum resolution,
, as a function
of the resolution of the forward tracking chambers. The upper left figure
has
resolution, while the upper right has the nominal
resolution. The lower left has
resolution and the lower right has
resolution.
 |
Figure:
Resolution as a function of momentum in the
to
angular bin. The forward tracking chamber has a
resolution of
.
 |
Figure:
Resolution as a function of momentum in the
to
angular bin. The forward tracking chamber has a
resolution of
.
 |
Figure:
Resolution as a function of momentum in the
to
angular bin. The forward tracking chamber has a
resolution of
.
 |
Figure:
Resolution as a function of momentum in the
to
angular bin. The forward tracking chamber has a
resolution of
.
 |
Curtis A. Meyer
10/20/1998